Wilkerson R39 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Wilkerson R39 herunter. Wilkerson R39 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Operating Pressure:
kPa PSIG bar
Maximum Inlet Pressure 1720 250 17.2
Ambient Temperature Range:
0°C to 80°C (32°F to 175°F)
Symbols
Installation
1. The regulator should be installed with reasonable accessibility
for service whenever possible - repair service kits are available.
Keep pipe and tubing lengths to a minimum with inside clean
and free of dirt and chips. Pipe joint compound should be used
sparingly and applied only to the male pipe - never into the
female port. Do not use PTFE tape to seal pipe joints - pieces
have a tendency to break off and lodge inside unit, possibly
causing malfunction.
2. Install regulator so that air flow is in the direction of arrow.
Installation must be upstream (high pressure) side and as
close to the devices it is to service (valve, cylinder, tool, etc.).
Mounting may be in any position.
3. Gauge ports are located on both sides of the regulator body.
It is necessary to install a gauge or pipe plugs into each port
during installation.
4. For protection against rust, pipe scale, and other foreign matter,
install a filter on the upstream (high pressure) side as close to
the regulator as possible.
Operation
1. Before turning on the air supply, turn the adjusting knob or
“T” handle counterclockwise until compression is released
from the control spring. Then turn on air supply and adjust
regulator to desired secondary pressure by turning adjusting
knob/handle clockwise. This permits pressure to build up slowly,
preventing any unexpected operation of the valve, cylinders,
tools, etc., attached to the line. Adjustment to desired secondary
pressure can be made only with primary pressure applied to
the regulator.
2. To decrease regulator pressure setting, always reset from a
pressure lower than the final setting desired. For example,
lowering the secondary pressure from 550 to 410 kPa (80 to 60
psig) is best accomplished by dropping the secondary pressure
to 350 kPa (50 psig), then adjusting upward to 410 kPa (60
psig).
Push the adjusting knob down to lock the pressure setting. On
the “T” handle units, tighten the hex nut against the bonnet to
lock setting.
Service
CAUTION:
SHUT OFF AIR SUPPLY and exhaust the primary and
secondary pressure before disassembling regulator unit.
(Turning the knob/handle counterclockwise reduces
regulator’s setting, but does not vent downstream pressure
on non-relieving regulators.)
Relieving Regulator
Adjustable
Non-Relieving Regulator
Adjustable
Pneumatic Division
Richland, Michigan 49083
269-629-5000
Introduction
Follow these instructions when installing, operating, or servicing
the product.
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
Disconnect air supply and depressurize all air lines connected to this
product before installation, servicing, or conversion.
Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
Medium must be moisture-free if ambient temperature is below
freezing.
Service according to procedures listed in these instructions.
Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
Warnings and specifications on the product should not be covered by
paint, etc. If masking is not possible, contact your local representative
for replacement labels.
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any failure
and review the information concerning the product or systems in the current
product catalog. Due to the variety of operating conditions and applications for
these products or systems, the user, through its own analysis and testing, is
solely responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of the
application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by The
Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
!
WARNING
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed maximum primary pressure rating.
!
Safety Guide
For more complete information on recommended application
guidelines, see the Safety Guide section of Pneumatic Division
catalogs or you can download the Pneumatic Division Safety
Guide at: www.parker.com/safety
Installation & Service Instructions
2R300C
1" Regulator Series
ISSUED: August, 2006
Supersedes: April, 2006
Doc. # 2R300C, ECN #060900, Rev 8
!
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - 269-629-5000

Application LimitsThese products are intended for use in general purpose compressed air systems only.Operating Pressure: kPa PSIG barMaxi

Seite 2 - Service Kits Available

1" Regulator Series 2R300CO-RingBodyPoppetAssemblyPistonBonnetPoppetReturnSpringSealO-RingLipsealControlSpringBonnetT Handle Adjusting KnobMount

Kommentare zu diesen Handbüchern

Keine Kommentare