Wilkerson ER08 Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
Parameter Number 39 Displays Current Software Version
Step 1 2 3
Press
3-6 seconds
Until
Display
Reads
Flashing Decimal
Description
Accesses
changeable
parameters.
Accesses
parameter no. 39.
Displays current
parameter value.
XXX = current
software version
40mm & 60mm Proportional Regulator 2R210
6
Set Deadband
Deadband is the minimum limit of accuracy at which the regulator is set for normal operation. The displayed value is X 10 mbar
and has a range between 4 (40 mbar) and 40 (400 mbar).
ParameterNumber13–SetDeadband(P20MustbeSetto0)
Step 1 2 3 4 5
Press
3-6 seconds
Until
Display
Reads
Flashing Decimal
Flashing Decimal
(value between
4 and 40)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 13.
Displays current
parameter value.
Incremental
value is
x 10 mbar
Edits parameter.
Accepts and saves
new parameter
setting.
Sequences to next
parameter.
or
or
or
ParameterNumber21–SetProportionalEffect(P20MustbeSetto0)
Step 1 2 3 4 5
Press
3-6 seconds
Until
Display
Reads
Flashing Decimal
Flashing Decimal
(value between
5 and 100)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 21.
Displays current
parameter value.
Edits parameter.
5 = fastest
regulation
100 = slowest
regulation.
Accepts and saves
new parameter
setting.
Sequences to next
parameter.
Proportional Effect
Sets the speed at which the regulator adjusts either filling or exhausting. The displayed value has a range between 5 (fastest
regulation) and 100 (slowest regulation).
or
or
Seitenansicht 5
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare