12 Series Modular Kits 83-960-000
Tighten the clamp screws alternating between the two screws
per connector until both screws are snug. Check the alignment
of each body to verify fit between body and clamp. The bottom
flange of the inner and outer clamp must be positioned below
the bottom edge of the body. Pressurize the assembly and
check for air leaks. If air leaks are found, depressurize the unit.
Loosen the outer clamp and check fit between the body and
clamps. Retighten the screws and check for air leaks.
Removal
Disconnect air supply and depressurize all air lines before
removing any modular units.
WARNING
Loosening the outer clamp screws may cause the
filter, regulator, lubricator, or accessory to dislodge
and fall. It is important to take necessary precautions
when loosening the outer clamp screws to prevent
the unit from falling and causing injury.
Loosen the outer clamp screws 8-9 turns. It is not necessary to
completely remove the screws. Slide the unit down until it
disconnects from the clamps. It may be necessary to pull the
outer clamp out when removing one of the units from the assembly.
GPA-96-301
thru
GPA-96-309 GPA-96-310
GPA-96-311
GPA-96-312
Wall Bracket
Inner Clamp
Outer Clamp
Clamp
Screw
Tube Seal (Assemble
Through Spacer)
racket Screw
orque To
.5 - 5.1Nm
40 - 45 In. Lbs.)
Start Screws Approximately 1 Turn By Han
Assemble To Bodies Or Port Blocks And
Torque To 3.4 - 4.5 Nm (30 - 40 In. Lbs.)
Figure 1
Figure 2
Service Kits Available
Description Kit Number
1/8" NPT Port Block GPA-96-301
1/4" NPT Port Block GPA-96-302
3/8" NPT Port Block GPA-96-303
1/8" BSPP Port Block GPA-96-304
1/4" BSPP Port Block GPA-96-305
3/8" BSPP Port Block GPA-96-306
1/8" BSPT Port Block GPA-96-307
1/4" BSPT Port Block GPA-96-308
3/8" BSPT Port Block GPA-96-309
Modular Connector Kit GPA-96-310
Wall Bracket Kit GPA-96-311
1/4" Lock Ball Kit GPA-96-312