Introduction
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Operating Pressure Maximum kPa PSIG bar
Bowl w/ Twist Drain / No Sight Gauge 2068 300 21.0
Bowl w/ Twist Drain and Sight Gauge 1700 250 17.0
Operating Temperature Ratings
Metal Bowl w/o Sight Gauge 0°F to 150°F (-18°C to 66°C)
Metal Bowl w/ Sight Gauge 0°F to 150°F (-18°C to 66°C)
Note: Air must be dry enough to avoid ice formation at temperatures below
32°F (0°C).
Symbol
Lubricator
w/ Manual Drain
Installation & Service Instructions:
83-950-000
SL2 Mist Lubricators
ISSUED: May, 2008
Supersedes: August, 2006
Doc.# 83950000, EN# 080328, Rev. 4
Richland, MI 49083 Tel: (269) 629-5000
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnectairsupplyanddepressurizeallairlinesconnectedtothis
productbeforeinstallation,servicing,orconversion.
• Operatewithin the manufacturer’s speciedpressure,temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Serviceaccordingtoprocedureslistedintheseinstructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• Afterinstallation,servicing,orconversion,airandelectricalsupplies
(when necessary) should be connected and the producttested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
• Warningsandspecicationsontheproductshouldnotbecoveredby
paint,etc.Ifmaskingisnotpossible,contactyourlocalrepresentative
forreplacementlabels.
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any failure
and review the information concerning the product or systems in the current
product catalog. Due to the variety of operating conditions and applications for
these products or systems, the user, through its own analysis and testing, is
solely responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of the
application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by The
Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
!
Installation
1. The lubricator should be installed with reasonable accessibility
for service whenever possible. Keep pipe or tubing lengths to a
minimum with inside clean and free of dirt and chips. Pipe joint
compound should be used sparingly and applied only to the
male pipe never into the female port. Do not use PTFE tape
to seal pipe joints pieces have a tendency to break off and
lodge inside the unit, possibly causing malfunction.
2. Install lubricator so air flows into port labelled “IN” on body.
3. Installation should be upstream of the device it is to lubricate
(valve, cylinders, tool, etc.) as possible.
SafetyGuide
For more complete information on recommended application
guidelines, see the Safety Guide section of Pneumatic Division
catalogs or you can download the PneumaticDivisionSafety
Guide at: www.wilkersoncorp.com
Service Kits Available
Description L10(1/2")
Drip Control Kit PS740N
Sight Gauge Kit SRP-96-026
Bowl Seal F10Y103-2VT
Body
Drip Control
Dome Assembl
y
Drip Spout
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - 32°F (0°C)

IntroductionFollow these instructions when installing, operating, or servicing the product.Application LimitsThese products are intended for use

Seite 2 - Operation and Service

SL2 Mist Lubricators 83-950-000 By counting the number of drops per minute in the sight dome, you can adjust to your requirements. Every drop visib